PIG LAUNCHER & RECEIVER
PIG LAUNCHER & RECEIVER
Introduction
The PIG LAUNCHERS & RECEIVERS are designed for introducing and removing all different types and sizes of PIGS in and out of a pipeline system. Both, PIG LAUNCHER & RECEIVER are equipped with closures according to ANSI codes. The standard receivers are provided with mechanical PIG passage indicators. They have a bypass or kick-out line that is approximately one-third the pipeline size. They are also equipped with gauge (display unit), vent and drain outlets.
Typical Application
- Sub Sea Application
- Off-shore Application
- On-Shore Application
- Gas Transmission Pipelines
Quick Opening Closure
THECO closures provide horizontal or vertical access to pipeline pig traps or any other type of pressure vessel. Our quick opening closures can be operated safely at remarkable speed; any size of closure can be opened or closed by one person in less than one minute, with no special tools required. Meet requirements of ASME VIII Div. I the closure hub and door are manufactured from materials that fully comply with the requirements of ASME SEC. II
/ ASTM and NACE MR 01-75 upon request.
Pig Trap Dimension
Pig Launcher
Barrel (in) | ۱۲ | ۱۶ | ۱۶ | ۲۰ | ۲۴ | ۳۰ | ۳۶ | ۴۲ | ۴۸ | ||
Main Line (in) | ۸ | ۱۰ | ۱۲ | ۱۶ | ۲۰ | ۲۴ | ۳۰ | ۳۶ | ۴۰ | ||
A (m) | ۳٫۹ | ۴ | ۴ | ۴٫۳ | ۳ | ۳٫۳ | ۳٫۴ | ۳٫۷ | ۳٫۷ | ||
E (m) | ۰٫۵ | ۰٫۵ | ۰٫۶ | ۰٫۶ | ۱ | ۱ | ۱ | ۱٫۵ | ۱٫۵ | ||
F (m) | ۴٫۵۶ | ۴٫۶۶ | ۴٫۷ | ۵ | ۳٫۵ | ۳٫۸ | ۳٫۹ | ۴٫۲ | ۴٫۲ | ||
H (m) | ۱۰۲۰ | ۹۸۰ | ۹۸۰ | ۹۳۰ | ۸۷۵ | ۸۰۰ | ۷۲۵ | ۶۵۰ | ۵۷۰ | ||
N1 (in) | ۴ | ۴ | ۴ | ۶ | ۸ | ۸ | ۱۰ | ۱۲ | ۱۶ | ||
N2 (in) | ۱/۲ | ۱/۲ | ۱/۲ | ۱ | ۱ | ۱ | ۱ | ۱ | ۱ | ||
N3 (in) | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ||
N4 (in) | ۲ | ۲ | ۲ | ۲ | ۴ | ۴ | ۴ | ۴ | ۴ | ||
N5 (in) | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ||
N6 (in) | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ||
N7 (in) | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ||
Trolly | No | No | No | No | Yes | Yes | Yes | Yes | Yes | ||
Tray | No | No | No | No | No | No | No | Yes | Yes | ||
JIB Crain | No | No | No | No | Yes | Yes | Yes | Yes | Yes | ||
Capacity (ton) | – | – | – | – | ۱ | ۱ | ۱ | ۲ | ۲ | ||
Internal Basket | No | No | No | No | Yes | Yes | Yes | Yes | Yes |
A =Kicker Distance From Main Line | N2 = Relief Nozzle
N3 = Pressure Indicator Nozzle |
|||||||||||
E = Main Line length | N4 = Vent Nozzle | |||||||||||
F = Barrel length | N5 = Pig Signaler Nozzle | |||||||||||
H = Launcher Height | N6 = Pressurizer Nozzle | |||||||||||
N1 = Kicker Line | N7 = Pressurizer Nozzle |
Pig Receiver
Barrel (in) | ۱۲ | ۱۶ | ۱۶ | ۲۰ | ۲۴ | ۳۰ | ۳۶ | ۴۲ | ۴۸ | ||
Main Line (in) | ۸ | ۱۰ | ۱۲ | ۱۶ | ۲۰ | ۲۴ | ۳۰ | ۳۶ | ۴۰ | ||
B (m) | ۳٫۹ | ۴ | ۴ | ۴٫۳ | ۳ | ۳٫۳ | ۳٫۴ | ۳٫۷ | ۳٫۷ | ||
C (m) | ۰٫۵ | ۰٫۵ | ۰٫۶ | ۰٫۶ | ۱ | ۱ | ۱ | ۱٫۵ | ۱٫۵ | ||
G(m) | ۴٫۵۶ | ۴٫۶۶ | ۴٫۷ | ۵ | ۳٫۵ | ۳٫۸ | ۳٫۹ | ۴٫۲ | ۴٫۲ | ||
H (m) | ۱۰۲۰ | ۹۸۰ | ۹۸۰ | ۹۳۰ | ۸۷۵ | ۸۰۰ | ۷۲۵ | ۶۵۰ | ۵۷۰ | ||
N1 (in) | ۴ | ۴ | ۴ | ۶ | ۸ | ۸ | ۱۰ | ۱۲ | ۱۶ | ||
N2 (in) | ۱/۲ | ۱/۲ | ۱/۲ | ۱ | ۱ | ۱ | ۱ | ۱ | ۱ | ||
N3 (in) | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ۱/۲ | ||
N4 (in) | ۲ | ۲ | ۲ | ۴ | ۴ | ۴ | ۴ | ۴ | ۴ | ||
N5 (in) | ۴ | ۴ | ۴ | ۴ | ۴ | ۴ | ۴ | ۶ | ۶ | ||
N6 (in) | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ||
N7 (in) | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ۲ | ||
Tray | No | No | No | No | No | No | No | Yes | Yes | ||
JIB Crain | No | No | No | No | Yes | Yes | Yes | Yes | Yes | ||
Capacity (ton) | – | – | – | – | ۱ | ۱ | ۱ | ۲ | ۲ | ||
Internal Basket | No | No | No | No | Yes | Yes | Yes | Yes | Yes |
B =Kicker Distance From Main Line | N3 = Pressure Indicator Nozzle | |||||||||||
C = Main Line length | N4 = Vent Nozzle | |||||||||||
G = Barrel length | N5 = Drain Nozzle | |||||||||||
H = Launcher Height | N6 = Pig Signaler Nozzle | |||||||||||
N1 = Kicker Line | N7 = Pressurizer Nozzle | |||||||||||
N2 = Relief Nozzle |
TYPE DESIGNATION
THPL – C- 600 – ۱۲/۸
|
Family Rating(Class) Max.W.Press.
THPL:Pig Launcher
THPR:Pig Receiver
MATERIALS
Part Name | Material |
Barrel | API 5L Gr. B, X42 |
Main Line | API 5L Gr. B, X42 |
Quick Opening Closure | St 52/ASTM A105 |
FLANGES | ASTM A105 |
Nozzles | API 5L Gr. B, X42 |
Sweepolet | ASTM A234 WPB |
Concentric/Eccentric Reducer | ASTM A234 WPHY/WPB |
Saddle | ASTM A283 Gr.C |
STUD BOLT&NUTS | ASTM A193-B7/ASTM A194 2H |
BASE Plate | ASTM A283 Gr.C |
NAME PLATE | St. St. |
Technical Specification
Inlet pressure | Pi: up to 2500 Psig |
Rating | ۱۵۰#-۳۰۰#-۶۰۰#-۹۰۰# |
Matching Pipe Line Range | Up to 40 |
Operating temperature | -۲۰ °c to + ۶۰ °c |
Drain Handling | Manual R AutomaticR |
Design code | ASME Sec VIIII-Div.1 |
Accessories | Tray R JIB Crain R |
PERFORM
Pig Launching & Receiving Procedures
Pig launchers are used to launch the pig into the pipeline, and pig receivers are used to receive the pigs after they have made a successful run.
The choice of these pig traps will depend on the type of pig to be run and pipeline design conditions. Provisions in the station design should include handling equipment for pigs 20″ and larger. Caution should be taken for liquid spillage from the pig traps.
Typical Pig Launching Procedures
The operational sequence described below is for general information only. It is not intended, nor should it be used, to train pigging system operators. Operating procedures will vary from one pipeline company to another. The following pig launching procedures can be used as a guideline for developing operating procedures.
Since company policies vary regarding whether the pig launcher is left on stream or isolated from the pipeline after the pig is launched, the operator should verify that the trap is isolated from the pipeline and depressurized before commencing any part of the launch procedure.
- Make sure that the isolation valve and the kicker valve are closed.
- In liquid systems, open the drain valve and allow air to displace the liquid by opening the vent valve. In natural gas systems, open the vent and vent the launcher to atmospheric pressure.
- When the pig launcher is completely drained (0 psig), with the vent and drain valves still open, open the trap (quick opening closure) door.
- Install the pig with the nose firmly in contact with the reducer between the barrel and the nominal bore section of the launcher.
- Clean the closure seal and other sealing surfaces, lubricate if necessary, and close and secure the closure door.
- Close the drain valve. Slowly fill the trap by gradually opening the kicker valve and venting through the vent valve.
- When filling is complete, close the vent valve to allow pressure to equalize across the isolation valve.
- Open the isolation valve. The pig is ready for launching.
- Partially close the main line valve. This will increase the flow through the kicker valve and behind the pig. Continue to close the main line valve until the pig leaves the trap into the main line as indicated by the pig signaler.
- After the pig leaves the trap and enters the main line, fully open the main line valve. Close the isolation valve and the kicker valve.
- The pig launching is complete.
Typical Pig Receiving Procedures
The operational sequence described below is for general information only. It is not intended, nor should it be used, to train pigging system operators. Operating procedures will vary from one pipeline company to another. The following pig receiving procedures can be used as a guideline for developing operating procedures. Since company policies vary regarding whether the pig receiver is left on stream or isolated from the pipeline, the operator should verify whether there is any internal pressure in the receiving trap before starting any part of the receiving procedures.
- Make sure the receiver is pressurized.
- Fully open the bypass valve.
- Fully open the isolation valve and partially close the main line valve.
- Monitor the pig signaler for pig arrival.
- Close the isolation valve and bypass valve.
- Open the drain valve and the vent valve.
- Check the pressure gauge on the receiver to assure the trap is depressurized (0 psi).
- Open the trap closure and remove the pig from the receiver.
- Clean the closure seal and other sealing surfaces, lubricate if necessary, and close and secure the trap (quick opening closure) door.
- Return the receiver to the original condition.